The ELK M1Gold Control currently holds the following listings, i.e. certifications or approvals:

• UL Standard 985, Household Fire Warning System Units
• UL Standard 1023, Household Burglar-Alarm System Units
• UL Standard 1635, Digital Alarm Communicator System Units,
• UL Standard 1637, Home Health Care Signaling Equipment
• ULC C1023-74, Canadian Standard for Household Burglar Alarm System Units,
• ULC S545-02, Canadian Standard for Residential Fire Warning System Control Units.
• UL Standard 1610, Central-Station Burglar-Alarm Units
• UL Standard 365, Police Station Connected Burglar Alarm Units and Systems
• UL Standard 609, Local Burglar Alarm Units and Systems
• ULC S303, Canadian Standard for Local Burglar Alarm Units and Systems
• ULC S304, Canadian Standard for Central and Monitoring Station Burglar Alarm Units
• CSA C22.2 No. 205-M1983 . Canadian Standard for Signal Equipment  
• CSFM California State Fire Marshall



MINIMUM SYSTEM CONFIGURATIONS FOR UL INSTALLATIONS

Household Burglary (UL 1023), Household Fire (UL 985), Digital Alarm Communicator (UL 1635) Listed Installations
   • At least one compatible keypad is needed for all applications.
   • At least one bell fixture is required for all applications.
   • Household Burg requires 4 hours of standby power. Limit combined continuous current draw from terminals +SAUX,
     +VAUX, +VKP, and connector J16 to 1 Amp max. and use one (1) 8 Ah battery.
   • Household Fire/Home Health Care requires 24 hours of standby power. Limit combined continuous current draw from
     terminals +SAUX, +VAUX, +VKP, and connector J16 to 500 mA and use two (2) 8 Ah batteries in parallel.
   • Force Arming and Auto Arming shall not be enabled
   • For Household Fire Listed Installations the indicating devices shall be a Wheelock 34T-12 or equivalent.
   • Initiating and indicating devices must be rated at 11.5 to 12.4 VDC.
   • For Household applications the minimum alarm cutoff time for the audible devices shall be 5 minutes.
   • Zone Swinger Shutdown shall not be enabled.
   • Remote Downloading shall not be used on UL Listed systems.
   • Communicator Dial Delay time shall be set to .0..
   • For Household Burg Listed Installations the maximum entry delay time shall be 45 seconds and the max. exit delay time
     shall be 60 seconds.
   • 24-hour communicator test transmission is required.
   • The silent keypad option shall not be enabled.

Home Health Care (UL 1637) Listed Installations
Requirements described under UL985 plus:
   • A minimum of two (2) keypads are required with one keypad powered from .+VKP. and one keypad powered from .+VAUX..

Commercial - Central Station (UL 1610), Police Station Connected (UL 365),Local Burglar Alarm (UL 609)
Listed Installations

Requirements described under UL1023 plus:
   • The Alarm Cutoff timer must be set to 00900 sec. (15 min.) or greater.
   • UL Commercial Burg requires 4 hours of standby power. Limit combined continuous current draw from terminals +SAUX,
     +VAUX, +VKP, and connector J16 to 450 mA max. and use one (1) 8 Ah battery.
   • An acceptable Commercial enclosure must be used (see Listed Enclosures below)
   • Tamper Switch(s) must be installed on the enclosure and connected to a 24 hour Burg Tamper defined Zone.
   • All Keypads need to be installed within the protected area (they have no tamper)
   • DO NOT USE an A B Attack Cabinet for the external sounder
   • A Whenever/And/Then rule should be written (using ElkRP software) to enable the Output 2 Siren to .chirp.
     upon closing ringback.

UL Canada Listed Installations (ULC S304 and ULC S303)
Requirements described under UL1023, 1610 plus:
   • Entry Delay must be set to 60 seconds or less.
   • Exit Delay must be set to 120 seconds or less.
   • The Alarm Cutoff timer must be set to 00900 sec. (15 min.) or greater.
   • UL Canada Commercial Burg requires 24 hours of standby power. Limit combined continuous current draw from terminals
     +SAUX, +VAUX, +VKP, and connector J16 is 450 mA max. and use two (2) 8 Ah batteries in parallel.
   • Zone Expanders must be in an acceptable Commercial enclosure (see Listed Enclosures below)



LISTED ENCLOSURES:

For Household Burglar or Household Fire Listed Installations
One of the following enclosures must be used:
   • ELK 14. Enclosure model ELK-SWB14 or ELK-UB14
   • ELK 28. Enclosure model ELK-SWB28
   • OnQ Legrand 14. Enclosure models 363474-01or 363474-11 utilizing the Universal Mounting plate part no. 364453.
     Not LISTED FOR CANADA
   • OnQ Legrand 28. Enclosure models 363475-01, 363475-11, 364591-01, 364591-02 or364591-11 utilizing the Universal
     Mounting plate part no. 364453. Not LISTED FOR CANADA
   • OnQ Legrand 42. Enclosure models 363476-01,363476-11,364592-01, 364592-02, or 364592-11 utilizing the Universal
     Mounting plate part no. 364453. Not LISTED FOR CANADA

For Commercial Listed Installations
One of the following enclosures must be used:
   • ELK-TB14 Tamper Resistant Enclosure
   • GE .Caddx. NX003-C with an ELK-61205684 Mounting Adapter Plate (See diagrams in M1 Installation Manual)