Brad Weeks

    The Honeywell serial number is a 7 digit number located on the wireless sensor.

    Have you enrolled the M1XRF2H?

    Have you created a Wireless Group in ElkRP2?

    If so:

    • Under Zone (Inputs) click on your Wireless Group x
    • Click on the zone number you want to configure
    • Set the Zone Definition, Type and any other option you need to select
    • Click “Wireless Setup”
    • Check “Enabled”
    • Supervised will either be 0 = Not Supervised for FOBs, 1 = Normal Supervision for Window/Door, 3 = Fire Supervision for Smoke Detectors
    • In the H ID box enter the 7 digit serial number for the Honeywell Wireless Sensor
    • In most cases the LOOP will equal 1 or reference the Honeywell instructions for the LOOP setting
    • Click SAVE and Close the “Change Wireless Zone” window
    • From the Zone page click “Send to Control” or “Send and Say”